This made me think that I may be able to install a standard 50 amp breaker in the pool's sub-panel and run the 4 wire #6 AWG THHN in conduit about 25' to the hot tub utilizing the integrated GFCI. If a single maintenance receptacle is provided. I was just about set on this plan when I re-read the installation instructions for this unit that said that if the unit was equipped with an integrated GFCI (see PDF Manuals/AIR/DELUXE/Electrical_Installation.pdf ). GFCI-protected receptacle outlet installed at the front and back of the. Convenience receptacle is required within 20 of the pool edge. Lighting circuit will supply (2) 12v transformers for (2) LED pool lights. The control panel contains (4) 120V 20A GFCI protected outlets, (1) 120/240V 50A outlet, (1) 120V 30A twistlock. Hayward SP2303VSP pump (230v variable speed) No heater or other powered equipment. I first thought that I would get a Connecticut Electric GFCI Load Center ,install a 50 amp breaker in the pool's sub-panel, run 4 wire #6 AWG THHN in conduit 3' to the new GFCI Load Center, then run 4 wire #6 AWG THHN in conduit about 25' to the hot tub. 14x33 fiberglass in-ground pool located 40 from house and sub-panel. When constructing a building, the electrical code requirements won’t be met if the structure doesn’t have this type of outlet at certain receptacle locations. The sub-panel has a 240v 20 amp breaker feeding the pool's pumps and a 110v 15 amp breaker feeding the blower. A GFCI outlet (ground fault circuit interrupter) is an important safety feature that’s installed in all Canadian homes and businesses. Since the main panel has no open slots and the pool sub-panel is closer, I would like to connect the hot tub to the pool's open slots in the sub-panel. Electrical panel for swimming pool with 12V AC safety transformer for LED and halogen lights. Pool sub-panel is fed by a 50 amp breaker on the home's main panel. The GFCI circuit breaker will shut off electricity in the event of a problem it will also trip when a short circuit or an electrical overload. Then, remove your cover and outlet to inspect the electrical box. Before you begin, turn off the main circuit breaker in your home. These are installed in a panel box to give protection to selected circuits. If at this point you still aren’t receiving power and the GFCI outlet won’t reset, the next step is to look for any loose connections within the outlet itself. The hot tub is located about 25' from the swimming pool sub-panel. This is the basic GFI outlet, as pictured above, which is installed to replace older, non-GFI outlets. I have a hot tub that requires a 50-60 amp GFCI power supply.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |